Product Description
Horiba LAQUAact PH130 Dual Channel pH/ORP/Ion/Temperature
Features Horiba LAQUAact PH130 Dual Channel pH/ORP/Ion/Temperature :
- Dual channel, switchable display
- Automatic pH calibration up to 5 points using NIST, USA or Custom pH buffers
- 0.01 pH resolution
- Offset and slope display
- Ion calibration up to 5 points
- Automatic / Manual temperature compensation and temperature calibration function
- Auto log data; Built-in memory can store up to 1000 data
- Auto-shut off (programmable: 1 to 30 minutes)
- Auto-Hold / Auto-Stable measurement
- Calibration alarm (programmable 1 to 400 days)
- Built-in electrode holder allows 2 electrodes to be attached on both sides of the meter
- Large backlit LCD: 52mm x 64mm
- RS232 output for connecting to computer or printer
- Casing is IP67 waterproof (for 30mins immersion in 1m depth of water) and dustproof
- Powered by 2 x AAA (LR03) or Ni-MH rechargeable batteries or power adaptor
- Packaged in new molded carry case
- 2 years meter warranty
Meter Kit Available
PH130-K
The appearance of items in the picture are subject to change in each region.
Package Details :
- LAQUAact PH130 Dual channel pH/ORP/Ion/Temp meter, built-in electrode holder, 2 x AAA batteries
- Instruction manual
- 9651-10D plastic-body, gel-filled pH electrode with integrated temperature sensor
- pH 4.01 / 7.00 / 10.01 buffers (60ml each)
- Carry case
PH130-KN: Kit with pH 4.01 / 6.86 / 9.18 NIST buffers (60ml each) is available upon request.
Specifications Horiba LAQUAact PH130 Dual Channel pH/ORP/Ion/Temperature :
-2.00 to 16.00 pH |
|
Resolution |
0.01 pH |
Accuracy |
± 0.01 pH |
Calibration Points |
Up to 5 |
Buffer Options |
USA, NIST, Custom |
ORP Range |
± 2000 mV |
Resolution |
1 mV |
Accuracy |
± 1mV or 1% of reading (whichever is greater) |
Ion Range |
0.00 µg/L to 1999 g/L |
Resolution |
3 significant digits |
Accuracy |
±0.8% F.S. |
Calibration Points |
Up to 5 |
Temperature Range |
-30.0 to 130.0°C |
Resolution |
0.1°C |
Accuracy |
± 0.4°C |
Calibration Option |
Yes |
Memory Data |
1000 |
Auto Log Data |
Yes |
Real-time Clock |
Yes |
Date / Time Stamp |
Yes |
Auto-Shut Off |
Yes (Programmable: 1 to 30 minutes) |
Auto-Hold / Auto-Stable |
Yes |
Offset / Slope Display |
Yes (Independent acid and alkaline slopes depending on calibration) |
Calibration Alarm |
Yes (Programmable: 1 to 400 days) |
Electrode Status |
On screen display |
Diagnostic Messages |
Yes |
Display |
Custom Backlit LCD |
Inputs |
2 x BNC, 2 x phono, DC sockets |
Output |
RS232 |
IP Rating |
IP67, shock-resistant |
Power Requirements |
2 x AAA (LR03) or Ni-MH rechargeable batteries or power adaptor |
Battery Life |
>500 hours |