Product Description
Fluke 810 Vibration Tester
CV. Syariftama Global Indonesia has a wide range of Fluke products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..
Fluke 810 Vibration Tester: When you need answers now…
Control unplanned maintenance time, prevent reoccurrence of problems, set repair priorities, and manage resources with a whole new approach to vibration testing.
The Fluke 810 Vibration Tester is the most advanced troubleshooting tool for mechanical maintenance teams who need answers now. Unique diagnostic technology helps you quickly identify and prioritize mechanical problems, just like a vibration analyst.
You take pride in your facility, team and work. You do whatever it takes to keep things up and running, but sometimes there isn’t enough time or resources to keep up with the workload, let alone be proactive in mechanical maintenance. The Fluke 810 Vibration Tester takes you one step further by combining a powerful diagnostic engine with a simple step-by-step process to report engine failures and their severity from the first measurement, with no trace of previous measurements. Overall vibration measurements and spectral diagrams provide technicians with the ability to quickly assess engine health, while advanced reports and executable recommendations give you the confidence you need to detect any problems at hand.
Specifications Fluke 810 Vibration Tester :
Diagnostic specifications |
Standard error |
|
Imbalance, looseness, misalignment and bearing damage |
|
Analysis for |
|
Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps, piston pumps, vane pumps, propeller pumps, screw pumps, rotary groove pumps/gear pumps/lobed pumps, piston compressors, centrifugal compressor, screw compressor, closed coupling machine, spindle |
|
Machine rotational speed |
|
Diagnostic details |
|
Plain text diagnosis, severity of damage (mild, moderate, severe, very severe), repair details, peaks captured, spectrum |
|
Electrical specifications |
Range |
|
A/D Converter |
|
Usable bandwidth |
|
Sampling |
|
Digital signal processing function |
|
Automatically configure, anti-alias filter, high-pass filter, decimation, overlapping, windowing, FFT, and averaging |
|
Sampling Speed |
|
Dynamic range |
|
Signal to noise ratio |
|
FFT Resolution |
|
Spectral windows |
|
Frequency unit |
|
Amplitude unit |
|
in/s, mm/s, VdB (US), VdB* (Europe) |
|
Non-volatile memory |
|
Micro SD memory card, 2 GB internal + user-accessible slot for additional storage |
|
General specifications |
Size (W x H x L) |
|
18.56 cm x 7.00 cm x 26.72 cm (7.30 in x 2.76 in x 10.52 in) |
|
Weight (with battery) |
|
Screen |
|
VGA, 320 × 240 Color (5.7 in diagonal) TFT LCD with LED backlight |
|
Input/Output Connection |
|
Three-axis sensor connection M12 4-pin
connection Single-axis sensor connection BNC
connection Tachometer connection 6-pin Mini DIN
connection PC connection Mini ‘B’ connection USB (2.0) |
|
Battery |
|
Battery type Lithium-ion, 14.8 V, 2.55 Ah
Battery charge time Three hours
Battery discharge time Eight hours (under normal conditions) |
|
AC Adapter |
|
Input voltage 100 Vac to 240 Vac
Input frequency 50/60 Hz |
|
Operating system |
|
Language Support |
|
English, French, German, Italian, Japanese, Portuguese, Chinese, Spanish |
|
warranty |
|
Environmental Specification |
Operating Temperature |
|
0 °C to 50 °C (32 °F to 122 °F) |
|
Storage temperature |
|
-20 °C to 60 °C (-4 °F to 140 °F) |
|
Operating Humidity |
|
10% to 95% RH, (non-condensing) |
|
Agent Approval |
|
CHINA RoHS, CSA, CE, C TICK, WEEE |
|
Electromagnetic compatibility |
|
EN 61326-1:2006, EN 61010:1:2001 2nd edition. |
|
Sensor specifications |
Sensor type |
|
Sensitivity |
|
Acceleration range |
|
Amplitude nonlinearity |
|
Frequency response |
|
Z: 2 – 7,000 Hz ± 3dB
X, Y: 2 – 5,000 Hz ± 3dB |
|
Power requirements (IEPE) |
18 V dc to 30 V dc, 2 mA to 10 mA |
|
Bias output voltage |
|
ground |
|
Sensor element design |
|
Case material |
|
Installation |
10-32 captive socket head screw, 2-pole earth magnet (48 lb tensile strength) |
|
Output connection |
|
Couple connection |
|
Non-volatile memory |
Compatible with TEDS 1451.4 |
|
Vibration limit |
|
Shock limit |
|
Electromagnetic sensitivity, equivalent g |
|
Sealing |
|
Temperature range |
-50 °C to 120 °C (-58 °F to 248 °F) ± 7 % |
|
warranty |
|
Tachometer specifications |
Size (H x L) |
|
2.86 cm x 12.19 cm (1.125 in x 4.80 in) |
|
Heavy |
|
Power |
|
Powered by Vibration Tester 810 |
|
Detection |
|
Range |
|
Accuracy |
|
6.0 to 5999.9 rpm: ± 0.01% and ± 1 digit
5999.9 to 99.999 rpm: ± 0.05 % and ± 1 digit |
|
Resolution |
|
Effective range |
|
1 cm to 100 cm (0.4 in to 39.27 in) |
|
Response time |
|
Control |
|
Transparent button to turn measurement on and off |
|
Interface |
|
Cable length |
|
warranty |
|
Tachometer accessories |
|
Reflective tape: 1.5 cm x 52.5 cm (0.59 in × 20.67 in) |
|
PC Viewer Software |
Minimum hardware requirements |
|
Operating system requirements |
|