Photron’s P900LL Series for Perkin Elmer AAS Instruments compatible with 51mm or 2″ base, 4 Pin Cableless, Coded Hollow Cathode Lamps which are designed to suit Perkin Elmer AAS instruments including PinAAcle 500, PinAAcle 900, AAnalyst 200, AAnalyst 400 AAnalyst 100, AAnalyst 300, AAnalyst 600, AAnalyst 700 and AAnalyst 800 .

Hollow cathode lamps produced by Photron are designed and manufactured to achieve all of the following fundamental requirements for a spectral line source

  • Intense emission of resonance (ground state derived) lines.
  • Narrow line width, for maximum sensitivity and linearity.
  • Minimal spectral interference from continuum emission, present in the cathode.
  • Rapid warm up to produce stable long term light emission.
  • Noise free operation. + Long running life and a 5 year shelf life.
  • Cathode materials and geometry achieve a combination of spectral purity and a suitable sputtering rate.

(A high sputtering rate will give high intensity at the expense of lamp life, sensitivity and linearity).

SMITH-HIEFTJE background correction

Photron lamps have been tested and found to work as well as lamps sold specifically for this technique, however due to the high energy pulse used, some elements will be consumed at a higher rate reducing lamp life.

Specification Photron P900LL Series Hollow Cathode Lamps Single Element :

No. Product Type Instrument Pin Type / Connectivity Wavelength Optical
Primary Wavelength Alternative Wavelengths Window material
P901LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Aluminium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 396.2nm 308.2 ~ 309.3 Quartz
P902LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Antimony Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 217.6nm 206.8 ~ 217.9nm Quartz
P903LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Arsenic Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 193.7nm 189.0 ~ 197.2nm Quartz
P904LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer –  Barium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 553.5nm 455.4 ~ 493.4nm Quartz
P905LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Beryllium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 234.9nm None Quartz
P906LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Bismuth Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 223.1nm 22.8 ~ 227.7nm Quartz
P907LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Boron Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 24.8nm 208.9nm Quartz
P908LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Cadmium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 228.8nm 326.1nm Quartz
P909LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer –  Calcium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 422.7nm 239.9nm Quartz
P910LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Cesium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 852.1nm 455.6nm Quartz
P911LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Cerium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 520.0nm 569.7nm Quartz
P912LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Chromium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 357.9nm 425.4 ~ 427.5nm Quartz
P913LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Cobalt Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 240.7nm 304.4nm Quartz
P914LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Copper Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 324.8nm 217.9nm ~ 218.2nm Quartz
P915LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Dysprosium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 421.2nm 404.6nm Quartz
P916LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Erbium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 400.8nm 389.3nm Quartz
P917LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Europium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 459.4nm 462.7nm Quartz
P918LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Gadolinium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 368.4nm 405.8 ~ 407.9nm Quartz
P919LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Gallium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 294.4nm 403.3 ~ 417.2nm Quartz
P920LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Germanium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 265.2nm 271.0nm Quartz
P921LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Gold Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 242.8nm 267.6nm Quartz
P922LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Hafnium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 307.8nm 268.2nm Quartz
P923LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Holmium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 410.4nm 425.4 ~ 405.4nm Quartz
P924LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Indium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 303.9nm 325.6 ~ 410.2nm Quartz
P925LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Iridium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 208.9nm 264.0 ~ 266.5nm Quartz
P926LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Iron Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 248.3nm 248.8 ~ 372.0nm Quartz
P927LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Lanthanum Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 550.1nm 403.7nm Quartz
P928LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Lead Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 217.0nm 283.3 ~ 261.4nm Quartz
P929LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer –  Lithium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 670.8nm 323.3nm Quartz
P930LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Lutetium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 335.9nm 356.7 ~ 337.6nm Quartz
P931LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Magnesium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 285.2nm 202.5nm Quartz
P932LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Manganese Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 279.5nm 279.8 ~ 280.1nm Quartz
P933LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Mercury Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 253.7nm None Quartz
P934LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Molybdenum Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 313.3nm 320.9nm Quartz
P935LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Neodymium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 492.5nm 463.4nm Quartz
P936LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Nickel Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 232.0nm 231.1 ~ 341.5nm Quartz
P937LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Niobium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 334.9nm 405.9 ~ 408.0nm Quartz
P938LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Osmium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 290.9nm 305.9 ~ 426.0nm Quartz
P939LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Palladium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 247.6nm 244.8 ~ 340.5nm Quartz
P940LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Platinum Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 265.9nm 264.7 ~ 299.8nm Quartz
P941LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Potassium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 766.5nm 404.4 ~ 769.9nm Quartz
P942LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Praseodymium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 495.1nm 513.3nm Quartz
P943LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Rhenium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 346.0nm 346.5nm Quartz
P944LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Rhodium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 343.5m 328.1 ~ 369.2nm Quartz
P945LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Rubidium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 349.9nm 392.6nm Quartz
P946LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Ruthenium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 349.9nm 392.6nm Quartz
P947LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Samarium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 429.7nm 476.0nm Quartz
P948LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Scandium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 391.2nm 390.8nm Quartz
P949LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Selenium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 196.0nm 204.0nm Quartz
P950LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Silicon Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 251.6nm 250.7 ~ 251.4nm Quartz
P951LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Silver Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 328.1nm 338.3nm Quartz
P952LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Sodium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 589.0nm 330.2 ~ 589.6nm Quartz
P953LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Strontium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 460.7nm 407.8m Quartz
P954LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Tantalum Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 271.5nm 275.8nm Quartz
P955LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Tellurium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 214.3nm 225.9nm Quartz
P956LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Terbium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 432.7nm 431.9 ~ 433.8nm Quartz
P957LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Thallium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 276.7nm 258.0nm Quartz
P958LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Thorium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 371.9nm None Quartz
P959LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Thulium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 371.8nm 436.0 ~ 410.6nm Quartz
P960LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Tin Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 235.5nm 224.6 ~ 266.1nm Quartz
P961LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Titanium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 364.3nm 365.4 ~ 399.0nm Quartz
P962LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Tungsten Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 255.1nm 294.7 ~ 400.9nm Quartz
P963LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Uranium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 358.5nm 256.6 ~ 351.4nm Quartz
P964LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Vanadium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 318.5nm 306.6 ~ 318.4nm Quartz
P965LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Ytterbium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 398.8nm 346.4nm Quartz
P966LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Yttrium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 410.2nm 414.2nm Quartz
P967LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Zinc Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 213.9nm 307.6nm Quartz
P968LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Zirconium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 360.1nm 468.7 ~ 354.8nm Quartz
P969LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Continuum Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless 170 ~ 380nm None Quartz
P970LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Calcium / Magnesium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless Quartz
P971LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Potassium / Sodium Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless Quartz
P972LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer- Copper / Zinc Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless Quartz
P973LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Chromium / Cobalt / Copper / Iron / Manganese / Nickel Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless Quartz
P974LL Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Phosphorus Perkin Elmer Atomic Absorption Spectrocopy (AAnalyst Series of Instruments) Four (4) Pin ~ Cableless Quartz
Notes 10,000 mA/hour timers are available (at additional cost) with this lamp.This lamp also features EPROM for digital coding

 

 

Photron P900LL Series Hollow Cathode Lamps Single Element –  Catalog

 


Jual Photron P900LL Series Hollow Cathode Lamps Single Element dengan harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilaya Indonesia.

Syariftama Global Indonesia memiliki beragam produk Photron cari berdasarkan jenis, atau model, atau filter berdasarkan merek untuk menemukan yang Anda cari. Jika Anda masih tidak dapat menemukannya hubungi kami di No Tlpon 0851 6306 9421 /SMS/Whatsapp.

Dalam pengiriman produk yang pelanggan beli, sebelumnya sudah kami cek untuk memastikan produk dalam keadaan baik dan siap kirim.

 

Product Enquiry

PRODUK TERKAIT

BUAT PERMINTAAN HARGA

Open chat
1
Butuh bantuan? chat WA
Terima Kasih Telah Menghubungi Kami.