There are four instruments in the DCM series of clampmeters, including the 400A AC current-only DCM310; the DCM320 which includes voltage and resistance measurement; the DCM330 Fork-Multimeter, which is an open fixed jaw design; and this, the DCM340. Capable of measuring AC and DC current up to 600A; AC and DC voltage up to 600V; resistance up to 400Ω; and frequency up to 400Hz, the DCM340 is the most versatile in the range.

Features Megger DCM340 Digital Clampmeter

  • DC and AC current and voltage
  • 600 A and 600 V
  • Resistance and continuity
  • 31/2 digit, 4000 count display with backlight
  • High resolution digital bargraph
  • Peak, min/max and data-hold functions
  • Zero-offset REL mode for comparative measurements
  • Supplied complete with test leads and carry case
  • IEC61010 CAT III 600 V

The DCM340 is a highly versatile instrument and ideal for use in the installation, maintenance, monitoring or checking of a.c. or d.c. electrical systems and equipment.

Specification Megger DCM340 Digital Clampmeter

AC Current Accuracy (50/60Hz) Accuracy (61 – 400Hz)
0 – 60A ±1.9% ± 7 digits ±2.5% ± 7 digits
60 – 400A ± 1.9% ± 5 digits ± 2.5% ± 5 digits
400 – 600A ± 2.5% ± 5 digits ± 2.9% ± 5 digits
DC Current Accuracy
0 – 60A ± 1.5% ± 10 digits
60 – 400A ± 1.9% ± 5 digits
400 – 600A ± 1.9% ± 10 digits
Voltage Accuracy (50-500Hz) Accuracy (DC)
0 – 400V ± 1.0% ± 5 digits ± 0.7% ± 2 digits
400 – 600V ± 1.0% ± 5 digits ± 0.7% ± 2 digits
Input Impedance 1MΩ // <100pF
Resistance and Continuity Accuracy
0 – 400Ω ± 1% ± 3 digits
Open Circuit Voltage 3V
Continuity Check Beeper sounds @ <30Ω
Frequency Resolution/Range Accuracy
20- 400Hz 1Hz ± 0.1% ± 2 digits
Sensitivity 3A
Peak Hold ±3% ± 15 digits
Sample Time 10ms
MIN/MAX Hold Add 15 digits to accuracy for AC and DC
Positional Error ±1% of reading
Overload Protection 600V and 600A rms
AC Conversion Average sensing rms indication calibrated to the rms value of a sine wave input
Auto Power Off 30 minutes after power on