MEGGER TDR1000/3P Handheld TDR

Product Description

MEGGER TDR1000/3P Handheld TDR

CV. Syariftama Global Indonesia has a wide range of Megger products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us.

Features MEGGER TDR1000/3P Handheld TDR

  • Adjustable display contrast
  • Resolution to 0.1 m
  • For use on Telecom TNV-3 circuit, or 150 V CAT IV power circuits
  • Power blocking filter not required
  • Environmental protection to IP54
  • Auto selected output impedance (between 25, 50, 75 and 100 Ω)
  • 2 ns pulse for near end fault location
  • AUTO option selecting gain and pulse for each range
  • Display distance in metres or feet
  • Uses five AA (LR6) primary cells

Specification MEGGER TDR1000/3P Handheld TDR

Description Time Domain Reflectometer
Part Number 1001-789
Included Accessories Hard case, user guide CD, retractable sheath fused test lead (1 pair)
Optional Accessories Miniature clip test lead set (1 pair), red and black probes and clips for use with all Megger TDR fused test leads, split conductor fused test lead set (1 pair)
Range 10 m, 25 m, 100 m, 250 m, 1000 m, 2500 m, 5000 m (30 ft, 75 ft, 300 ft, 750 ft, 3000 ft, 7500 ft, 15000 ft)
Accuracy ±1% of range ± pixel at 0.67 VF
[Note- The measurement accuracy is for the indicated cursor position only and is conditional on the velocity factor being correct.]
Resolution 1% of range
Input Protection This instrument complies with IEC61010-1 for connection to live systems up to 150 V CAT IV when used with the supplied fused test lead set.
Output Pulse 5 volts peak to peak into open circuit
Gain Set for each range with three user selectable steps (in Manual operating mode)
Velocity Factor Variable from 0.2 to 0.99 in steps of 0.01
TX Null Automatic
Power Down Automatic after 5 minutes with no key press
Backlight Stays on for 1 minute with no key press
Battery Five LR6 (AA) type batteries, Manganese alkali or nickel metal-hydride cells
Battery Life Up to 14 hours (Typical)
Dimensions 230 x 115 x 48 mm ( 9.0 x 4.5 x 2.0 inches)
Weight 0.6 kg (1.32 lbs)
Case ABS
Connectors Two 4 mm-safety terminals
Test Lead (19 mm spaced TDR1000/3P): 1 pair 1.5 m retractable sheath, fitted with 500 mA FF HBC 1 kV 50 kA fuse
Display 256 x 128 pixel Graphics LCD
Operating Temperature Range & Humidity -15 °C to +50 °C (5 °F to 122 °F)
Storage Temperature Range & Humidity -20 °C to 70 °C (-4 °F to 158 °F)
Safety When using the supplied fused test lead set this instrument complies withIEC61010-1 for connection to live systems with less than 300 V between the terminals and up to 150 V CAT IV to earth
EMC Complies with Electromagnetic Compatibility Specifications (Light industrial) BS EN 61326-1, with a minimum performance of ‘B’ for all immunity tests