Lutron AM-4234SD Hot Wire Anemometer

Category Tag

Lutron AM-4234SD Hot Wire Anemometer

  • Complete set with two probes : Hot wire anemometer probe and Humidity/Temp. probe
  • Combination of hot wire and standard thermistor, deliver rapid and precise measurements even at low air velocity value
  • Slim probe, ideal for grilles & diffusers
  • Air velocity : m/s, Ft/min, Km/h, Knot, Mile/h
  • Air flow ( CFM, CMM ) measurement
  • Air temperature ( ℃,℉ )
  • Air Temp. used thermistor sensor, fast response time
  • Humidity : 10 to 95 %RH, Dew point, Wet bulb

Product Description

Lutron AM-4234SD Hot Wire Anemometer

CV. Syariftama Global Indonesia has a wide range of Lutron products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..

Features

  • Complete set with two probes : Hot wire anemometer probe and Humidity/Temp. probe.
  • Air velocity : 0.2 to 35.0 m/s, wide range and high precision.
  • Slim probe, ideal for grilles & diffusers.
  • Air velocity : m/s, Ft/min, Km/h, Knot, Mile/h,
  • Air flow (CFM, CMM) measurement.
  • Air temperature (C, F)
  • Air Temp. used thermistor sensor, fast response time.
  • Humidity : 10 to 95 %RH, Dew point, Wet bulb.
  • Type K, Type J thermocouple thermometer.
  • Real time SD memory card Datalogger, it Built-in Clock and Calendar, real time data recorder , sampling time set from 1 second to 3600 seconds.
  • SD card capacity: 1GB to 16GB (SD Card is optional)
  • LCD with green light backlight, easy reading.
  • Can default auto power off or manual power off.
  • Data hold, record max. and min. reading.
  • Microcomputer circuit, high accuracy.
  • Power by UM3/AA (1.5 V) x 6 batteries or DC 9V adapter.
  • RS232/USB PC COMPUTER interface.

Specifications

  • Circuit: Custom one-chip of microprocessor LSI circuit.
  • Display:
    º LCD size : 52 mm x 38 mm
    º LCD with green backlight ( ON/OFF ).
  • Function:
    º Anemometer ( Air velocity, Air flow ).
    º Humidity/Temp. meter.
    º Type J/K thermometer.
  • Measurement Unit:
    º Air velocity :
    * m/S (meters per second)
    * Km/h ( kilometers per hour )
    * Ft/min ( FPM, feet per minute )
    * Knots ( nautical miles per hour )
    * Mile/h ( mph, miles per hour )
    º Air temperature : ℃,℉
    º Air flow : CMM, CFM.
    º Humidity/Temp. : %RH/ ℃ or ℉.
    º Dew point ( Humidity ) : ℃ or ℉.
    º Wet bulb ( Humidity ) : ℃ or ℉.
    º Type K/ Type J thermometer : ℃,℉
  • Sensor Structure:
    º Air velocity & Air flow : Tiny glass bead thermistor.
    º Air temperature : Thermistor.
    º Humidity : Precision capacitance humidity sensor.
    º Type K, Type J thermometer : Type K/J thermocouple probe * Probes are optional.
  • Datalogger Sampling Time Setting range:
    º Auto: 1 second to 3600 seconds @ Sampling time can set to 1 second, but memory data may loss.
    º Push the data logger button once will save data one time. @ Set the sampling time to 0 second @ Manual mode, can also select the 1 to 99 position ( Location ) no.
  • Memory Card: SD memory card. 1 GB to 16 GB. * It recommend use memory card 4 GB
  • Advanced setting:
    º Set clock time ( Year/Month/Date,Hour/Minute/ Second )
    º Set sampling time
    º Auto power OFF management
    º Set beep Sound ON/OFF
    º Decimal point of SD card setting
    º SD memory card Format
    º Set thermometer type to Type K or Type J
    º Set temperature unit to ℃ or ℉
    º Set air flow type ( CFM/USA, CMM/EURO )
    º Set air flow area dimension
  • Temperature Compensation: Automatic temp. compensation for the Anemometer function and the type K/J thermometer.
  • Data Hold: Freeze the display reading.
  • Memory Recall: Maximum & Minimum value.
  • Sampling Time of Display: Approx. 1 second.
  • Data Output: RS 232/USB PC computer interface.
  • Operating Temperature: 0 to 50 ℃.
  • Operating Humidity: Less than 85% R.H.
  • Power Supply:
    º AAlkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent.
    º ADC 9V adapter input. ( AC/DC power adapter is optional ).
  • Power Current:
    º Normal operation ( w/o SD card save data and LCD Backlight is OFF) : Approx. DC 30 mA
    º When SD card save the data and LCD Backlight is OFF) : Approx. DC 50 mA
  • Weight: 347 g/ 0.76 LB. * Meter only
  • Dimension:
    º Main instrument : 182 x 73 x 47.5 mm ( 7.1 x 2.9 x 1.9 inch )
    º Telescope Probe : Round, 12 mm Dia x 280 mm ( min. length ). Round, 12 mm Dia x 940 mm ( max. length ).

Accessories Included

  • Instruction manual
  • Hot Wire Probe
  • Humidity/Temp probe
  • Hard case CA-06

Optional Accessories

  • Batere AA = 6pcs
  • SD Card
  • Type K Thermocouple
  • DC Adaptor

 

SYARIFTAMA GLOBAL INDONESIA adalah Supplier Lutron AM-4234SD di Jawa Barat & Jakarta dan juga menjual Brand Lutron diantaranya Lutron DO-5510 Dissolved Oxygen Meter, Lutron DO-5510HA Dissolved Oxygen Meter, Lutron DO-5512SD Dissolved Oxygen Meter, Lutron DO-5519E Dissolved Oxygen Meter, Lutron OXPB-09N Dissolved Oxygen Probe dll. lihat produk kami lainnya di sini KMT,JSI,SGMatau hubungi kami lewat Whatsapp 0821-3010-0456. atau via email [email protected] [email protected].

 

Dalam pengiriman produk yang pelanggan beli, sebelumnya sudah kami cek untuk memastikan produk dalam keadaan baik dan siap kirim.

Product Enquiry

PRODUK TERKAIT

BUAT PERMINTAAN HARGA

Open chat