Product Description
Copley Friability Tester FRV 1000 And FRV 2000
CV. Syariftama Global Indonesia has a wide range of Copley products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..
Friability Testers (Uncoated Tablets)
The basic Friability Tester Model FR 1000/2000 comprises of a single or dual drums rotated at a fixed speed of 25 rpm. The standard friability drum has an inside diameter of 287 mm and a depth of 38 mm and is fitted with a curved baffle which subjects the tablets to be tested to a drop of 156 mm. The Friability Tester Model FRV 1000/2000 also features either one or two drums, but allows variable speed between 20 and 60 rpm to be programmed. Number of turns or test duration can also be programmed into the tester.
The sample (normally 10 tablets) to be tested is first weighed and then placed into the drum. The drum is then rotated 100 times, any loose dust from the sample removed and the sample re-weighed. The friability drum features apertures behind the baffle, such that the tablets can be added and removed from the drum automatically at the beginning and end of the test.
The Friability of the sample is given in terms of % weight loss (loss in weight expressed as a percentage of the original sample weight). A maximum weight loss of not more than 1% is considered acceptable for most tablets.
Abrasion drums for carrying out tests into the attrition of tablets caused by the product rubbing together during transit are also available on request.
Friability Testers (Granules and Spheroids)
In many cases, such as with hard coated and uncoated tablets, granules and spheroids, it is impossible to determine the friability of the dosage form using a conventional tablet friability tester even if the test time is extended simply because the resistance is such that no measurable attrition is obtained – the energy imparted by the friability tester is just not sufficient to generate quantifiable changes in surface mass.
The Friabimat SA-400 is a new instrument specifically designed to address this particular problem by offering an alternative method of friability measurement.
For the purpose of the test, the sample is confined within a standard 105 mL glass bottle horizontally mounted on the end of an oscillating arm. The abrasive action is generated by the horizontal shaking movement of the oscillating arm which causes the samples to rub against and collide with each other and/or the internal surfaces of the sample container.
The intensity of the abrasive action and the duration of the test can be adjusted via the controls mounted on the front panel between 0 and 400 oscillations per minute and 0 and 9999 seconds respectively.
For comprehensive product details, specifications and part numbers, please request a copy of our brochure “Quality Solutions for the Testing of Pharmaceuticals”.
Specification Copley Friability Tester FRV 1000 And FRV 2000 :
- Constant Speed: 25 rpm ± 1 (for model FR 1000, FR 2000)
- Speed range: 20 – 60 rpm; ± 1 (for model FRV 1000, FRV 2000). The speed is controlled via the membrane
- keypad in steps of 1 rpm
- As on the FR Series, the duration of the test can be selected in either revolutions of the drum (1-999.999) or
- time (up to 99 hours, 59 minutes, 59 seconds).
- During the test run, the nominal test duration and remaining test duration, in either revolutions or time, is
- indicated on the LCD screen, together with the selected speed.
- Control a membrane keypad and 4-lines LCD screen
- Dimensions (mm):
- FR 1000 / FRV 1000 = 290 mm (W) x 360 mm (D) x 350 mm (H)
- FR 2000 / FRV 2000 = 342 mm (W) x 360 mm (D) x 350 mm (H)
Copley Friability Tester FRV 1000 And FRV 2000 – Datasheet
Produk asli Kami distributor langsung Copley Harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilaya Indonesia.