Product Description
Fluke TS-100 Network Cable Fault Finder
CV. Syariftama Global Indonesia has a wide range of Fluke products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..
Pencari kesalahan kabel yang mudah digunakan, pengelola kabel dan kabel, serta generator nada.
Fitur Fluke TS-100 Network Cable Fault Finder :
- Bekerja pada dua atau lebih kabel konduktor hingga 3.000 kaki (915 meter)
- Secara instan mengukur jarak untuk membuka atau kesalahan apa pun dari salah satu ujung pasangan kabel apa pun
- Pembuat nada SmartTone™ yang dipatenkan secara positif mengidentifikasi pasangan
- Mengukur jarak kabel pada spool
- Mengukur terus-menerus saat ‘Aktif’
- Menampilkan pembacaan jarak daripada bentuk gelombang
- Layar LED terang besar
- Operasi satu tombol
- Deteksi tegangan tinggi
- Bukti kelembaban
- Opsi kabel saluran tambahan tersedia untuk kabel koaksial (konektor-F) dan aplikasi lainnya
Spesifikasi Fluke TS-100 Network Cable Fault Finder :
General Speciffications :
Power : 4 AA alkaline batteries, provide 50 hours of operation.
Reverse Battery Protection : No damage to the tester will occur if the batteries are installed backwards.
Input Protection : 250 V rms ac, continuous or intermittent
Moisture : If the tester is exposed to water, some may get inside, but it will suffer NO DAMAGE. See the information on moisture under “Maintenance”.
Impedance Range : 35 Ω to 330 Ω with auto-compensation within this range. Cables with an impedance outside this range will not be properly tested and may produce erratic or incorrect readings.
Maximum Length : 2500 feet on certain cable types, 2000 feet on most cable types, and 500 feet on very lossy cables. The tester will display –Err if the cable is too long to be correctly measured.
Representative Maximum Cable Length : 2500 feet: CAT-5 Twisted Pair 2000 feet: 12/2 ac Wire 1000 feet: RG-6/U TV Coax 500 feet: RG-174/U Coax
Minimum Length : No minimum length Minimum non-zero reading is 2 feet
Length Accuracy : ±2 feet for cables less than 10 feet ±5 feet for cables longer than 10 feet and shorter than 200 feet ±3 % and ±5 feet for cables longer than 200 feet
High Voltage Detection : An ac voltage of more than 5 V rms will trigger the High Voltage Warning.
Measurement Rate : Maximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity.
VOP : Adjustable from -20- to -99-, retained during power off. Default to -66- when batteries are changed
Measurement Technology : Time Domain Reflectometry (TDR) with 50 Ω drive impedance, 6 V maximum pulse height
Low Battery : Indicator flashes when battery voltage falls below 4.1 V
Tone Injection : Approximately 1 kHz at an amplitude of 80 % of battery voltage. Variable frequency and cadence. Tone characteristic is changed as cable condition changes to “normal-open” from any other condition.
Cable Type : Virtually all two or more conductor cables
Temperature Range
Operating Storage : 32 °F to 131 °F (0 °C to 55 °C) -40 °F to 158 °F (-40 °C to 70°C)
Humidity
Operating : 0 % to 80 %
Storage : 0 % to 100 %
Weight : 1 lb
Certifications and Compliance :
CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1
Fluke TS-100 Datasheet