Hanna HI 98194 Multiparameter

Category Tag

Hanna HI 98194 Multiparameter

  • HI-98194 provides multiparameter measurement in a compact and rugged IP67 waterproof enclosure. Ideal for demanding application, this meter features our rugged, quick connect multi-function probe with field replaceable sensors. The HI-98194 measures pH/mV, ORP, Conductivity, TDS, Resistivity, Salinity, Seawater, Dissolved Oxygen, Atmospheric Pressure and Temperature.
  • Also available in 10m, 20m and 40m cables. See table below for details. Prices will vary.
  • A backlit, graphic LCD provides easy to read resolution even in low-lit areas. A combination of dedicated and soft keys allows easy, intuitive operation in a choice of languages.
  • HI-98194 allows users to store up to 45,000 continuous or log-on demand samples with logging intervals from one second to three hours. Logged data can be later transferred to a PC with the HI-920015 micro USB cable and Hanna software.

Product Description

Hanna HI 98194 Multiparameter

Key features:

  • IP67 rated waterproof, rugged enclosure for meter, IP68 for probe
  • Colour coded, field replaceable sensors
  • Auto sensor recognition
  • Automatic logging of up to 45,000 samples
  • Store measurement data at the press of a button
  • On-screen context specific help is readily available at the press of a button
  • PC connectivity via opto-isolated micro-USB with Hanna software
  • Up to 360 hours of battery life, powered by (4) 1.5Vbatteries

Specification:

pH/mV Range 0.00 to 14.00 pH/± 600.0 mV
Resolution 0.01 pH/ 0.1 mV
Accuracy ±0.02 pH/ ±0.5 mV
Calibration automatic one, two or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
ORP Range ±2000.0 mV
ORP Resolution 0.1 mV
ORP Accuracy ±1.0 mV
ORP Calibration automatic at one custom point (relative mV)
EC Range 0 to 200 mS/cm (absolute EC up to 400 mS/cm)
EC Resolution Manual: 1μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; automatic: 1μS/cm from 0 to 9999 μS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
EC Accuracy ±1% of reading or ± 1μS/cm whichever is greater
EC Calibration automatic single point, with six standard solutions (84μS/cm, 1413μS/cm, 5.00mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range 0 to 400.0 ppt (g/L) (the maximum value depends on the TDS factor)
TDS Resolution manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); automatic: 1ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 PPT(g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 pp (g/L)
TDS Accuracy ±1% of reading or ±1 ppm (mg/L) whichever is greater
TDS Calibration based on conductivity or salinity calibration
Resistivity Range 0 to 999999 Ω.cm; 0 to 1000.0 kΩ.cm; 0 to 1.0000 MΩ.cm
Resistivity Resolution dependent on resistivity reading
Resistivity Calibration based on conductivity or salinity calibration
Salinity Range 0.00 to 70.00 PSU
Salinity Resolution 0.01 PSU
Salinity Accuracy ±2% of reading or ±0.01 PSU whichever is greater
Salinity Calibration based on conductivity calibration
Seawater σ Range 0.0 to 50.0 σt, σ0, σ15
Seawater σ Resolution 0.1 σ t, σ0, σ 15
Seawater σ Accuracy ±1 σ t, σ0, σ 15
Seawater σ Calibration based on conductivity or salinity calibration
Dissolved Oxygen Range 0.0 to 500.0%, 0.00 to 50.00 ppm
DO Resolution 0.%; 0.01 ppm (mg/L)
DO Accuracy 0.0 to 300.0%; ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%; ±3% of reading; 0.00 to 30.00 ppm (mg/L); ±1.5% of reading or ±0.10 ppm (mg/L). whichever is greater; 30.00 ppm (mg/L) to 50.00 ppm (mg/L); ±3% of reading
DO Calibration automatic one or two points at 0.100% or one custom point
Atmospheric Pressure Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Atmospheric Pressure Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Atmospheric Pressure Accuracy ±3mm Hg within ±15°C from the temperature during calibration
Atmospheric Pressure Calibration automatic at one custom point
Temperature Range -5.00 to 55.00°C
Temperature Resolution 0.01°C
Temperature Accuracy ±0.15°C
Temperature Calibration Automatic at one custom point
Additional Specifications
 Maximum probe immersion Depth – 20 metres
  Temperature compensation automatic from -5 to 55°C
  Logging Memory 45,000 records (continuous logging or log-on demand of all parameters
  Logging Interval one second to three hours
 PC Connectivity via USB (with Hanna PC software)
  Environment 0 to 50°C; RH 100% IP67
  Battery Type/Life 1.5V AA batteries (4)/approximately 360 hours of continuous use without backlight (50 hours with backlight)
  Dimensions/Weight 185 x 93 x 35.2 mm/400g

Hanna HI 98194 Datasheet 

CV. SYARIFTAMA GLOBAL INDONESIA   adalah distributor dan Supplier Hanna HI 98194 Multiparameter di Jawa Barat & Jakarta dan juga menjual Brand Hanna  dll. lihat produk kami lainnya di sini  di sini KMT,SGI,SGM atau hubungi kami lewat Whatsapp 0821-3010-0456. atau via email [email protected], [email protected] & [email protected]

 