Product Description
Hanna HI83399 Portable COD and Multiparameter Photometer and pH Meter
HI83399 benchtop photometer measures 40 different key water and wastewater quality parameters using 73 different methods that allow for multiple ranges and variations in chemistry for specific applications. The Chemical Oxygen Demand (COD) parameter is included for industrial and municipal wastewater treatment. The Phosphorous and Nitrogen parameters included are beneficial to municipal wastewater treatment customers that need to monitor their biological and chemical nutrient removal process.
Features/Benefits Hanna HI83399 Portable COD and Multiparameter Photometer and pH Meter
On-screen Features
Method Selection
Users can easily select any one of the 60 measurement methods via the dedicated METHOD button.
Users can easily select any one of the 60 measurement methods via the dedicated METHOD button.
Data Logging
Up to 1000 measurement readings can be logged with user and sample ID and recalled for future use.
Up to 1000 measurement readings can be logged with user and sample ID and recalled for future use.
Digestion Parameters Features
Cuvette Adapter
The HI83399 is supplied with a 16 mm cuvette adapter that accepts digestion vials.
The HI83399 is supplied with a 16 mm cuvette adapter that accepts digestion vials.
Digestion Vial Methods
Compatible with COD (EPA, ISO, and mercury free methods), Nitrogen and Phosphorous reagetns packaged in 16 mm digestion vial. Reagents are sold separately.
Compatible with COD (EPA, ISO, and mercury free methods), Nitrogen and Phosphorous reagetns packaged in 16 mm digestion vial. Reagents are sold separately.
COD Reactor for Digestion Vials
A COD reactor is used to heat the digestion vials. The digestion vials must be heated to a specific temperature for a period time making the HI839800 an important accessory required to have a complete wastewater treatment monitoring system.
A COD reactor is used to heat the digestion vials. The digestion vials must be heated to a specific temperature for a period time making the HI839800 an important accessory required to have a complete wastewater treatment monitoring system.
Specification Hanna HI83399 Portable COD and Multiparameter Photometer and pH Meter
SKU | HI83399-02 |
---|---|
Product Name | Water & Wastewater Multiparameter (with COD) Photometer and pH meter – HI83399 |
Quote Required | Yes |
pH Range | Photometer |
pH Resolution | Photometer |
pH Accuracy | Photometer |
pH Calibration | Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01) |
pH Temperature Compensation | Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used |
pH CAL Check (electrode diagnostics) | |
pH Method | Photometer |
pH-mV Range | ±1000 mV |
pH-mV Resolution | 0.1 mV |
pH-mV Accuracy | ±0.2 mV |
Dissolved Oxygen Range | 0.0 to 10.0 mg/L (as O2) |
Dissolved Oxygen Resolution | 0.1 mg/L |
Dissolved Oxygen Accuracy | ±0.4 mg/L ±3% of reading |
Dissolved Oxygen Measurement Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method |
Absorbance Range | 0.000 to 4.000 Abs |
Absorbance Resolution | 0.001 Abs |
Absorbance Accuracy | +/-0.003Abs @ 1.000 Abs |
Alkalinity Range | Freshwater |
Alkalinity Resolution | 1 mg/L |
Alkalinity Accuracy | ±5 mg/L ±5% of reading |
Alkalinity Method | Colorimetric method |
Aluminum Range | 0.00 to 1.00 mg/L (as Al3+) |
Aluminum Resolution | 0.01 mg/L |
Aluminum Accuracy | ±0.04 mg/L ±4% of reading |
Aluminum Method | Adaptation of the aluminon method |
Ammonia Range | Low Range |
Ammonia Resolution | Low and Medium Range |
Ammonia Accuracy | Low Range |
Ammonia Method | Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method |
Anionic Surfactants Range | 0.00 to 3.50 mg/L (as SDBS) |
Anionic Surfactants Resolution | 0.01 mg/L |
Anionic Surfactants Accuracy | ±0.04 mg/L ±3% of reading |
Anionic Surfactants Method | Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS |
Bromine Range | 0.00 to 8.00 mg/L (as Br2) |
Bromine Resolution | 0.01 mg/L |
Bromine Accuracy | ±0.08 mg/L ±3% of reading |
Bromine Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method. |
Calcium Range | Freshwater |
Calcium Resolution | 1 mg/L |
Calcium Accuracy | Freshwater |
Calcium Method | Freshwater |
Chemical Oxygen Demand Range | Low Range |
Chemical Oxygen Demand Resolution | 1 mg/L |
Chemical Oxygen Demand Accuracy | Low Range |
Chemical Oxygen Demand Method | Adaptation of the USEPA 410.4 ISO dichromate methods Mercury-free dichromate green method (LR & MR); dichromate method (HR) |
Chloride Range | 0.0 to 20.0 mg/L (as Cl⁻) |
Chloride Resolution | 0.1 mg/L |
Chloride Accuracy | ±0.5 mg/L ±6% of reading at 25 °C |
Chlorine Dioxide Range | 0.00 to 2.00 mg/L (as ClO2) |
Chlorine Dioxide Resolution | 0.01 mg/L |
Chlorine Dioxide Accuracy | ±0.10 mg/L ±5% of reading |
Chlorine Dioxide Method | Adaptation of the Chlorophenol Red method. |
Free Chlorine Range | 0.00 to 5.00 mg/L (as Cl2) Ultra Low Range |
Free Chlorine Resolution | 0.01 mg/L Ultra Low Range |
Free Chlorine Accuracy | ±0.03 mg/L ±3% of reading Ultra Low Range |
Total Chlorine Range | 0.00 to 5.00 mg/L (as Cl2) Ultra Low Range |
Total Chlorine Resolution | 0.01 mg/L Ultra Low Range |
Total Chlorine Accuracy | ±0.03 mg/L ±3% of reading Ultra Low Range |
Chlorine Method | Adaptation of the EPA 330.5 DPD method Free Chlorine (ULR) & Total Chlorine (UHR) |
Chromium, Hexavalent Range | Low Range |
Chromium, Hexavalent Resolution | 1 μg/L |
Chromium, Hexavalent Accuracy | Low Range |
Chromium, Hexavalent Method | Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method. |
Color, Water Range | 0 to 500 PCU (Platinum Cobalt Units) |
Color, Water Resolution | 1 PCU |
Color, Water Accuracy | ±10 PCU ±5% of reading |
Color, Water Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method. |
Copper Range | Low Range |
Copper Resolution | 0.001 mg/L; 0.01 mg/L |
Copper Accuracy | Low Range |
Copper Method | Adaptation of the EPA bicinchoninate method |
Cyanuric Acid Range | 0 to 80 mg/L (as CYA) |
Cyanuric Acid Resolution | 1 mg/L |
Cyanuric Acid Accuracy | ±1 mg/L ±15% of reading |
Cyanuric Acid Method | Adaptation of the turbidimetric method |
Fluoride Range | Low Range |
Fluoride Resolution | 0.01 mg/L; 0.1 mg/L |
Fluoride Accuracy | Low Range |
Fluoride Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method |
Hardness, Total Range | Low Range |
Hardness, Total Resolution | 1 mg/L |
Hardness, Total Accuracy | Low Range |
Hardness, Total Method | Adaptation of the EPA recommended method 130.1 |
Hardness, Calcium Range | 0.00 to 2.70 mg/L (as CaCO3) |
Hardness, Calcium Resolution | 0.01 mg/L |
Hardness, Calcium Accuracy | ±0.11 mg/L ±5% of reading |
Hardness, Calcium Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method |
Hardness, Magnesium Range | 0.00 to 2.00 mg/L (as CaCO3) |
Hardness, Magnesium Resolution | 0.01 mg/L |
Hardness, Magnesium Accuracy | ±0.11 mg/L ±5% of reading |
Hardness, Magnesium Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method |
Hydrazine Range | 0 to 400 μg/L (as N2H4) |
Hydrazine Resolution | 1 μg/L |
Hydrazine Accuracy | ±4% of full scale reading |
Hydrazine Method | Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method |
Iodine Range | 0.0 to 12.5 mg/L (as I2) |
Iodine Resolution | 0.1 mg/L |
Iodine Accuracy | ±0.1 mg/L ±5% of reading |
Iodine Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method |
Iron Range | Low Range |
Iron Resolution | 0.001 mg/L; 0.01 mg/L |
Iron Accuracy | Low Range |
Iron Method | Low Range |
Magnesium Range | 0 to 150 mg/L (as Mg2+) |
Magnesium Resolution | 1 mg/L |
Magnesium Accuracy | ±5 mg/L ±3% of reading |
Magnesium Method | Adaptation of the Calmagite method |
Manganese Range | Low Range |
Manganese Resolution | 1 μg/L; 0.1 mg/L |
Manganese Accuracy | Low Range |
Manganese Method | Low Range |
Molybdenum Range | 0.0 to 40.0 mg/L (as Mo6+) |
Molybdenum Resolution | 0.1 mg/L |
Molybdenum Accuracy | ±0.3 mg/L ±5% of reading |
Molybdenum Method | Adaptation of the mercaptoacetic acid method |
Nickel Range | Low Range |
Nickel Resolution | 0.001 mg/L; 0.01 g/L |
Nickel Accuracy | Low range |
Nickel Method | Low Range |
Nitrate Range | 0.0 to 30.0 mg/L (as NO3–– N) 16 mm vial |
Nitrate Resolution | 0.1 mg/L |
Nitrate Accuracy | ±0.5 mg/L ±10% of reading 16 mm vial |
Nitrate Method | Adaptation of the cadmium reduction method 16 mm vial |
Nitrite Range | Freshwater Low Range |
Nitrite Resolution | Freshwater |
Nitrite Accuracy | Freshwater Low Range |
Nitrite Method | Low Range and Seawater |
Nitrogen, Total Range | Low Range |
Nitrogen, Total Resolution | 0.1 mg/L; 1 mg/L |
Nitrogen, Total Accuracy | Low Range |
Nitrogen, Total Method | Chromotropic acid method |
Oxygen, Scavenger Range | 0 to 1000 μg/L (as DEHA) .0.00 to 1.50 mg/L as Carbohydrazide *0.00 to 2.50 mg/L as Hydroquinone ^0.00 to 4.50 mg/L as ISO-ascorbic acid |
Oxygen, Scavenger Resolution | 1 μg/L (DEHA); 0.01 mg/L |
Oxygen, Scavenger Accuracy | ±5 μg/L ±5% of reading |
Oxygen, Scavenger Method | Adaptation of the iron reduction method |
Ozone Range | 0.00 to 2.00 mg/L (as O3) |
Ozone Resolution | 0.01 mg/L |
Ozone Accuracy | ±0.02 mg/L ±3% of reading |
Ozone Method | Colorimetric DPD Method |
Phosphate Range | Freshwater Low Range |
Phosphate Resolution | Freshwater |
Phosphate Accuracy | Freshwater Low Range |
Phosphate Method | Freshwater Low Range |
Phosphorous, Acid Hydrolyzable Range | 0.00 to 1.60 mg/L (as P) |
Phosphorous, Acid Hydrolyzable Resolution | 0.01 mg/L |
Phosphorous, Acid Hydrolyzable Accuracy | ±0.05 mg/L or ±5% of reading |
Phosphorous, Acid Hydrolyzable Method | Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method |
Phosphorous, Reactive Range | Low Range |
Phosphorous, Reactive Resolution | 0.01 mg/L; 0.1 mg/L |
Phosphorous, Reactive Accuracy | Low Range |
Phosphorous, Reactive Method | Low Range |
Phosphorous, Total Range | Low Range |
Phosphorous, Total Accuracy | Low Range |
Phosphorous, Total Resolution | Low Range |
Phosphorous, Total Method | Low Range |
Potassium Range | 0.0 to 20.0 mg/L (as K) |
Potassium Resolution | 0.1 mg/L |
Potassium Accuracy | ±3.0 mg/L ±7% of reading |
Potassium Method | Adaptation of the Turbidimetric Tetraphenylborate method |
Silica Range | Low Range |
Silica Resolution | 0.01 mg/L; 1 mg/L |
Silica Accuracy | Low Range |
Silica Method | Low Range |
Silver Range | 0.000 to 1.000 mg/L (as Ag) |
Silver Resolution | 0.001 mg/L |
Silver Accuracy | ±0.020 mg/L ±5% of reading |
Silver Method | Adaptation of the PAN method |
Sulfate Range | |
Sulfate Resolution | 1 mg/L |
Sulfate Accuracy | ±5 mg/L ±3% of reading |
Sulfate Method | Turbidimetric – Sulfate is precipitated with barium chloride crystals |
Zinc Range | 0.00 to 3.00 mg/L (as Zn) |
Zinc Resolution | 0.01 mg/L |
Zinc Accuracy | ±0.03 mg/L ±3% of reading |
Zinc Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method |
Input Channels | 1 pH electrode input and 5 photometer wavelengths |
pH Electrode | digital pH electrode (not included) |
Photometer/Colorimeter Light Source | 5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters |
Photometer/Colorimeter Light Detector | silicon photodetector |
Bandpass Filter Bandwidth | 8 nm |
Bandpass Filter Wavelength Accuracy | ±1 nm |
Cuvette Type | round, 24.6 mm |
Number of Methods | 128 max. |
GLP | calibration data for connected pH electrode |
Display | 128 x 64 pixel LCD with backlight |
Logging Type | log on demand with user name and sample ID optional input |
Logging Memory | 1000 readings |
Connectivity | USB-A host for flash drive; micro-USB-B for power and computer connectivity |
Power Supply | 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) |
Battery Type/Life | 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement |
Environment | 0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensing |
Weight | 1.0 kg (2.2 lbs.) |
Dimensions | 206 x 177 x 97 mm (8.1 x 7.0 x 3.8″) |
Ordering Information | HI83399 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual. |
Hanna HI83399 Portable Datasheet