Product Description
Horiba LAQUAact PC110 Dual Channel pH/ORP/Cond/TDS/Res/Sal/Temp
Features Horiba LAQUAact PC110 :
- Dual channel, switchable display
- Automatic pH calibration up to 5 points using NIST, USA or Custom pH buffers
- 0.01 pH resolution
- Offset and slope display
- Automatic / Manual temperature compensation and temperature calibration function
- Automatic and manual conductivity calibration up to 4 points
- Adjustable reference temperature and temperature coefficient
- Selectable cell constant and measurement unit
- Conductivity and total dissolvd solids (TDS) conversion
- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl
- Two (2) salinity calibration curves: NaCl, Seawater
- Auto log data; Built-in memory can store up to 1000 data
- Auto shut-off (programmable: 1 to 30 minutes)
- Auto-Hold / Auto-Stable measurement
- Calibration alarm (programmable: 1 to 400 days)
- Built-in electrode holder allows 2 electrodes to be attached on both sides of the meter
- Large backlit LCD: 52mm x 64mm
- RS232 output for connecting to computer or printer
- Casing is IP67 waterproof (for 30mins immersion in 1m depth of water) and dustproof
- Powered by 2 x AAA (LR03) or Ni-MH rechargeable batteries or power adaptor
- Packaged in new molded carry case
- 2 years meter warranty
Meter Kit Available
PC110-K
The appearance of items in the picture are subject to change in each region.
Package Details :
- LAQUAact PC110 Dual channel pH/ORP/Cond/TDS/Res/Sal/Temp meter, built-in electrode holder, 2 x AAA batteries
- Instruction manual
- 9651-10D plastic-body, gel-filled pH electrode with integrated temperature sensor
- 9382-10D plastic-body, Titanium/Platinum black, conductivity probe (k=1.0) with integrated temperature sensor
- pH 4.01 and 7.00 buffers, 1413µS/cm and 12.88 mS/cm conductivity solutions (60ml each)
- Carry case
PC110-KN: Kit with pH 4.01 and 6.86 NIST buffers (60ml each) is available upon request.
Specifications Horiba LAQUAact PC110 Dual Channel pH/ORP/Cond/TDS/Res/Sal/Temp :
pH Range |
-2.00 to 16.00 pH |
Resolution |
0.01 pH |
Accuracy |
± 0.01 pH |
Calibration Points |
Up to 5 |
Buffer Options |
USA, NIST, Custom |
ORP Range |
± 2000 mV |
Resolution |
1 mV |
Accuracy |
± 1mV or 1% of reading (whichever is greater) |
Conductivity Range |
…µS/cm to 2000 mS/cm |
Resolution |
0.05% F.S. |
Accuracy |
±0.6% F.S.; ±1.5% F.S. > 18.0 mS/cm |
Reference Temperature |
15 to 30°C (adjustable) |
Temperature Coefficient |
0.0 to 10.0% (adjustable) |
Cell Constant |
0.1, 1.0, 10.0 (selectable) |
Calibration Points |
Up to 4 (Auto / Manual) |
Unit Setting |
µS/cm, mS/cm, S/m (Auto-ranging) |
TDS Range |
…ppm to 1000 ppt (TDS factor=0.5) |
Resolution |
0.01 ppm / 0.1 ppt |
Accuracy |
±0.1% F.S. |
Calibration Curves |
EN27888, 442, Linear, NaCl |
Resistivity Range |
0.000 Ω•cm to 200.0 MΩ•cm |
Resolution |
0.05% F.S. |
Accuracy |
±0.6% F.S.; ±1.5% F.S. > 18.0 mΩ•cm |
Salinity Range |
0.0 to 100.0 ppt / 0.00 to 10.00% |
Resolution |
0.1 ppt / 0.1 % |
Accuracy |
0.2% F.S. |
Calibration Curves |
NaCl, Seawater |
Temperature Range |
-30.0 to 130.0°C |
Resolution |
0.1°C |
Accuracy |
± 0.4°C |
Calibration Option |
Yes |
Memory Data |
1000 |
Auto Log Data |
Yes |
Real-time Clock |
Yes |
Date / Time Stamp |
Yes |
Auto-Shut Off |
Yes (Programmable: 1 to 30 minutes) |
Auto-Hold / Auto-Stable |
Yes |
Offset / Slope Display |
Yes (Independent acid and alkaline slopes depending on calibration) |
Calibration Alarm |
Yes (Programmable: 1 to 400 days) |
Electrode Status |
On screen display |
Diagnostic Messages |
Yes |
Display |
Custom Backlit LCD / Dual Channel / Switchable Display |
Inputs |
2 x BNC, 2 x phono, DC sockets |
Output |
RS232 |
IP Rating |
IP67, shock-resistant |
Power Requirements |
2 x AAA (LR03) or Ni-MH rechargeable batteries, or power adaptor |
Battery Life |
>200 hours |