Lutron DW-6093 3 Phase Power Analyzer

Category Tag

Lutron DW-6093 3 Phase Power Analyzer 3 Phase Power Analyzer

  • Analysis for 3 phase multi-power system, 1P/2W, 1P/3W, 3P/3W, 3P/4W
  • Voltage & Current are the True RMS value
  • True Power ( KW、- MW、- GW ) measurement
  • Apparent Power ( KVA、- MVA、- GVA ) measurement
  • Reactive Power ( KVAR – MVAR、- GVAR) measurement
  • Watt-Hour ( WH、- SH、- QH、- PFH )
  • Power Factor( PF )、- Phase Angle( Φ )
  • Voltage measurement range : 10 to 600 ACV

Product Description

Lutron DW-6093 3 Phase Power Analyzer 3 Phase Power Analyzer

CV. Syariftama Global Indonesia has a wide range of Lutron products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us.

Used by technicians in conducting energy audits where the data obtained can be used for prevention or preventive maintenance to prevent leaks or other electrical disturbances that disrupt the ongoing production process.

Features

  • Analysis for 3 phase multi-power system, 1P/2W, 1P/3W, 3P/3W, 3P/4W
  • 3 current probes max 1200A AC (CP-1201) are included
  • Current range : 0.2 to 1200 ACA –>CP-1201
  • Current probe input signal/ranges with selection:
    Input signal (ACV): 200 mV/300 mV/500 mV/1 V/2 V/3 V
  • Meter can cooperate with other universal current probes
  • Voltage & Current are the True RMS value
  • True Power (KW, MW, GW)
  • Apparent Power (KVA, MVA, GVA)
  • Reactive Power (KVAR, MVAR, GVAR)
  • Watt-Hour (WH, SH, QH, PFH)
  • Power Factor (PF), Phase Angle (Degree)
  • Voltage range : 10 to 600 ACV
  • Programmable CT ratio (1 to 600) and PT ratio (1 to 1000)
  • ACV input impedance is 10 Mega ohms
  • Safety Standard : IEC 1010, CAT III 600V

Specifications

  • Circuit: Custom one-chip of microprocessor LSI circuit
  • Display:
    º LCD Size : 81.4 X 61 mm ( 3.2 X 2.4 inch )
    º Dot Matrix LCD (320 X 240 pixels ) with back light.
  • Measurement:
    º ACV
    º ACA
    º AC WATT ( True Power ), AC WATT( Apparent Power ), AC WATT( Reactive Power )
    º Power factor
    º Phase angle
    º Frequency
  • Wire connections: 1P/2W, 1P/3W, 3P/3W, 3P/4W
  • Voltage ranges: 10 ACV to 600 ACV, auto range.
  • Current probe input signal and range:
    º Current probe input signal volage ( ACV ) : 200mV/300mV/500mV/1V/2V/3V
    º Current probe input current range ( ACA ) : 20 A/200A/2000A (1200 A)/30A/300A/3000A
    º Meter can cooperate the universal current probe.
  • Safety standard: IEC1010 CAT III 600 V.
  • ACV input impedance: 10 Mega ohms.
  • Range select:
    º ACV: Auto range.
    º ACA: Manual range.
  • Clamp frequency response: 40 Hz to 1 KHz.
  • Spec. tested frequency: 45 to 65 Hz.
  • Over load protection:
    º ACV: 720 ACV rms
    º ACA: 1300 ACA with clamp probe
  • Over Indicator:
    º LCD display show ” OL “.
    º The data save into the SD card will show ” 9999 ” or ” 999 ” ( overleap the decimal point )
  • Under Indicator:
    º LCD display show ” UR “.
    º The data save into the SD card will show ” 9999 ” or ” 999 ” ( overleap the decimal point )
  • Data Hold: Freeze the display reading.
  • Data Record: SD Card Record.
  • Sampling Time: Approx. 1 second.
  • Power ON/OFF: Manual OFF by push button.
  • Real time data logger:
    º Real time data logger, saved the data into SD memory card and down load the all the measured value with the time information ( year/month/data/hour/minute/second ) down load to the Excel
    º Sampling time for data logger : 2 seconds to 7200 seconds, the during of setting step are 2 seconds.
  • Data Output USB/RS232: RS232 computer serial interface :
    º Connect the optional USB cable USB-01 will get the USB plug.
    º Connect the optional RS232 cable UPCB-02 will get the RS232 plug.
  • Operating Temperature: 0 to 50℃ ( 32 to 122℉ ).
  • Operating Humidity: Less than 80% R.H..
  • Power Supply:
    º DC 1.5V, AA ( UM-3 ) Battery X 8 PCs (Alkaline or heavy-duty battery).
    º AC to DC 9V power adapter.
  • Power Consumption:
    º Meter : 300 DCmA.
    º Clamp : 34 DCmA.
  • Clamp max conductor Size: 50 mm ( 2.0 inch ) Dia.
  • Weight:
    º Meter : 948g ( includes batteries )
    º Clamp ( includded cable ) : 467g
  • Dimension:
    º Meter : 225 X 125 X 64 mm ( 8.86 X 4.92 X 2.52 inch )
    º Clamp : 210 X 64 X 33mm ( 8.3 X 2.5 X 1.3 inch )
    º Clamp Jaw : 86 mm (3.4 inch)- outside

Accessories Included : 

  • 4 PCs Test Leads
  • 4 PCs Alligator clips
  • 3 PCs Clamp Probe 1200A (CP-1201)
  • AC to DC 9V adapter
  • 4 GB SD card
  • Carrying bag
  • Instruction Manual
  • Certificate Calibration

 

 

SYARIFTAMA GLOBAL INDONESIA adalah Supplier Lutron DW-6093 di Jawa Barat & Jakarta dan juga menjual Brand Lutron diantaranya Lutron DO-5510 Dissolved Oxygen Meter, Lutron DO-5510HA Dissolved Oxygen Meter, Lutron DO-5512SD Dissolved Oxygen Meter, Lutron DO-5519E Dissolved Oxygen Meter, Lutron OXPB-09N Dissolved Oxygen Probe dll. lihat produk kami lainnya di sini KMT,JSI,SGMatau hubungi kami lewat Whatsapp 0821-3010-0456. atau via email [email protected] [email protected].

 

Dalam pengiriman produk yang pelanggan beli, sebelumnya sudah kami cek untuk memastikan produk dalam keadaan baik dan siap kirim.

Product Enquiry

PRODUK TERKAIT

BUAT PERMINTAAN HARGA

Open chat
1
Butuh bantuan? chat WA
Terima Kasih Telah Menghubungi Kami.